Figure 2. Block diagram of the swarm-base FLC system





                       Robot 1


                                                                                     Moving  swarm behavior
                      Robot (i-1)        Fuzzi cation  Inference engine  Defuzzi cation
                                                                                    direction  control

                      Robot (i+1)
                                                                                          Robot(i) ’s deployment
                                                                                              location
                       Robot (n)

                     Sensor’s location                  Robot(i) ’s FLC
                      and reading




                                                                               particles. Usually keep the charging
              Figure 3. Comparison of D AVE,S(A)   and D AVE,S(SMPS)
                                                                               level as low as possible to prevent
                                                                               ions repulsion. In other words, DC
                                                                               measures the quantity of  “active”
                   90
                                                                                                          [3]
                                                                               surface  of atom or ion attachment .
                           Dilution Tunnel Data                                             1         dn  dn
                                                                                               = const
                           Roadway Data (1/2 Day)                              S A  =  √(3kT/m)n    dt              dt  ….....(1)
                           Loading Dock 04/25/00
                           Loading Dock 04/28/00
                   60
                           Loading Dock 05/01/00                               Where SA: Active surface
                           1:1 Intersection                                    k  : Boltzmann constant
                  D Ave,S(A)  (nm)                                             T : Temperature
                                                                               m : Mass

                   30                                                          n : concentration of atoms
                                                                               After the surface concentration and
                                                                               the total number concentration N
                                                                               of the particles are measured , we
                                                                               can assume the aerosol has the same
                   0
                     0               30               60              90       surface area concentration and
                                          D Ave,S(SMPS)  (nm)                  calculate the  hypothetical mono-
                                                                               disperse aerosol.


                                                                                       1   0.5
                                                                               D AVE,S  =(  πN  ) …...................................(2)

              of a miniaturized device matrix of   response time and high installation
              such instruments to form a particle   cost so makes it difficult to use in   Where D Ave,S  : Diameter of a hypo-
              detection and alarm system, which   the vast territory and changing   thetical mono-disperse aerosol
              may be established by the formation   environment in the cleanroom.  Major type of aerosol in cleanroom
              of condensation particle counter                                 is nuclei mode. The nuclei mode
              (CPC) and the diffusion charging                                 particle size < 100nm can pass
              sensor (DC). The device should   The Diffusion Charging          t h r oug h  t he  h i g h- e f f ic ie ncy
              have high  time  resolution and   Sensor (DC)                    particulate air (HEPA) filter in the
              cover very low concentration range   The DC signal is controlled by   fan filter units (FFU). The larger
              and ultrafine particle diameters.   Brownian diffusion, and the current   particles exceeding 100 nm for
              Standard scanning mobility particle   sensor measures the direct diffusion   example coarse particle mode will
              sizer(SMPS) has relatively slow   charging by the surface area of the   be removed in the makeup air unit