 圖廿二、直流供電系統示意圖  [5]






 Optional Onsite
 dc Power
                                 New Vision
 100-600 Vdc

 Optional Onsite dc
 Generator and/or Storage  MPPT  Optional Onsite
 dc Power

 B
 380 Vdc Bus way
 (or Cabling)                     อ ൥ อ ٝ
 A

 ac Input                         鈀 (Pd) 觸媒於超純水中去除雙氧水以抑制銅腐蝕之應用
 Bidirectional  dc
 Converter  ECC                   Inhibition of Copper Corrosion by Removal of H 2 O 2  from CO 2 -Dissolved Water Using Palladium Catalysts
 ICT Racks
 Bidirectional  dc
 Meter  UPS                       物聯網簡介
                                  Internet of Things and the Application for Fab’s Facility System
 ac Flow
 Optional Onsite  dc Flow
 ac Generator                     科技一日千里:哇…3D 列印建廠不是夢!
 FIT (Feed-Intariff) Flow
 Physical Data Center             Cutting-edge Technology Enables the Impossibility : Building New Fabs with 3D Printing
                                  智慧型火災影像偵測系統之應用
                                  The Application of Intelligent Video Fire Detection System



 3,000 多 萬 的 Row cooler 設 置 費  參考文獻   Corporation High Density Data Center
 An Operational Review.
 用,機房坪效將更佳。  [1]  北科大李魁鵬,電信機房節能應用技術。  [15] John Musilli & Brad Ellison, IT@Intel
 [2]  Lawrence Berkeley National Labs,   White Paper, Facilities Design for
 Benchmarking: Data Centers,   High-density Data Centers.
 Dec 2007, http://hightech.lbl.gov/  [16] Jay Kyathsandra & Chuck Rego, The
 benchmarkingdc-charts.html  Efficient Datacenter.
 [3]  綠基會,2012 年非生產性質行業能源查
 結論   核年報。  [17] 綠智網,Tier 功能驗證。
 [4]  DCDA Consultant, Data center.   [18] ABB Review, Data Centers Designed
 for Uptime, 2014.
 [5]  Guy AlLee and William Tschudi, 380   [19] Emerson Network Power, Conducting
 Vdc Brings Reliability and Efficiency to   an Accurate Utility Cost Analysis Based
 高密度電腦機房將是未來的趨勢,  Sustainable Data Centers.  on UPS efficiency.
 如何讓它不中斷供應也是台積電面  [6]  林憲文、楊璉華,新一代機房管理。
 [7]  Thermal Guidelines for Data Processing
 臨的問題,所有廠務系統及運算儲  Environments, 2nd Edition, ASHRAE
 Datacom Series 1, 2011.
 存單元均需包含備援,導致設備裝
 [8]  經濟部能源委員會,節約能源技術手冊。
 置量均大上一倍,UPS 運轉負載量  [9]  財團法人台灣綠色生產力基金會,空調
 僅 在 30~40% 之 間, 其 效 率 並 不  系統管理與節能手冊。
 [10] Humidity Excursions in Facebook
 佳,直流供電可提高使用效率及減  Prineville Data Center, http://www.
 少需要的面積。  electronics-cooling.com/2012/12/
 humidity-excursions-in-facebook-
 prineville-data-center/.
 相關廠務設施進行節能手法,及機
 [11] Otto Van Geet, Trends in Data Center
 櫃冷熱通道分離以外,自然冷卻通  Design – ASHRAE Leads the Way to
 風方式是最節能方式,但必須考慮  Large Energy Savings.
 [12] Jay Park, Open Computer Project Data
 當地氣候條件及空氣品質,減少額  Center v1.0.
 外設置過濾系統。若能選擇在適當  [13] Google 資料中心省錢法!引河水做冷
 卻,處理後排回河中,http://asset3.
 地點單獨設置一電腦機房,利用  t17.techbang.com.tw/topics/12646-by-
 春、秋季節採自然冷卻方式,機房  google-data-centers-to-save-money-
 water-cooled-rear-back-in-the-river.
 用電每年將可減少 126 萬以上。  [14] Paul Vaccaro & David Seger, Intel




                                                                                                          73
                                                                                                          7 7
                                                                                                          73
 72                                                                                     NEWFABJOUOURNAL      JUNE201012012 2014 4  73
                                                                                                           3
                                                                                                           3
                                                                                                   UNE
                                                                                                   J
                                                                                                    E
                                                                                                    E
                                                                                                    E
                                                                                               NAL
                                                                                          F
                                                                                          FA
                                                                                         W
                                                                                        NEW
                                                                                        NEW FAB JOURNAL         JUNE 2014
                                                                                              RNAL
                                                                                               NAL
                                                                                             U
                                                                                           B
                                                                                             U
   71   72   73   74   75   76   77   78   79   80   81