廠務季刊  Facility Journal 2023


              空氣污染(NMHC)減量之空污設備(洗滌塔)用水水質改善
              Improvement  Of  Water  Quality  In  Washing  Towers  For  Air  Pollution
              Reduction(NMHC)
                                                                                   文│陳建全│新竹廠務二部




                                                        摘要




                  摘要                                    F12P3 以源頭分流改善及提升污染物防制設備處理效能的兩
                                                        個主軸方式,致力於各項空氣污染減量 ( 污染物為硝酸、磷
                  1. 前言
                                                        酸、硫酸、氫氟酸、鹽酸、氯氣、氨氮、VOCs(NMHC 代表 ),
                  2. 文獻探討                               達到源頭減量、降低排放濃度。盤查分析發現 LWSC 來源水
                                                        含有機質,造成酸性排氣煙囪出口 NMHC 濃度偏高的原因,
                    2.1  NMHC相關處理技術
                                                        影響煙囪出口排出氣體的品質。
                    2.2  有機廢水處理技術探討
                                                        透過文獻探討、廠區有限的空間及建置成本的考量,選擇以
                    2.3  雙膜模型
                                                        物化法處理系統 (ACF 塔單元串聯薄膜設備單元 ) 進行規劃,
                                                        建置一套有效率的 AOR 有機廢水回收處理系統;提升 LSS供
                  3. 研究方法
                                                        應水源的品質,將水中 TOC 由 10.0ppm 降低至 3.1ppm。
                    3.1  酸性排氣煙囪NMHC源頭盤查                 洗滌塔水質改善 LWSC NMHC 出口濃度改善 93%(avg.9.24
                    3.2  LWSC水源分析與變更測試                  降至 0.54ppm),有效減少煙囪出口 NMHC 排放總量
                                                        0.50Ton/Year,提升廠區煙囪排放品質,達到空污設備供水
                    3.3  水質改善流程規劃
                                                        水質精鍊需求,減少空氣污染。
                  4. 分析與結果                              關鍵詞 : 揮發性氣體、洗滌塔
                    4.1  系統上線後供應水質檢測
                                                        F12P3  is  committed  to  the  reduction  of  various  air
                    4.2  水質改善對於NMHC濃度                   pollution(pollutants are nitric acid, phosphoric acid,
                       改善與排放減量成效                        sulfuric  acid,  hydrofluoric  acid,  hydrochloric  acid,
                                                        chlorine, ammonia nitrogen, VOCs(Representative of
                    4.3  AOR處理系統對各廠區的
                                                        NMHC) to achieve source reduction and reduce emission
                       適用性建議分析
                                                        concentration. Inspection and analysis found that the
                                                        LWSC source water contains organic matter, which causes
                  5. 結論
                                                        the high concentration of NMHC at the acidic exhaust
                  參考文獻                                  chimney outlet and affects the quality of the exhaust gas
                                                        at the chimney outlet.
                  作者介紹
                                                        Through literature review, limited space in the factory
                                                        and consideration of construction costs, we chose to use
                                                        a physical and chemical treatment system(ACF tower unit
                                                        in series membrane equipment unit) for planning and
                                                        build an efficient AOR organic wastewater recovery and
                                                        treatment system ; improve LSS The quality of the water
                                                        supply reduces the TOC in the water from 10.0ppm to
                                                        3.1ppm. The water quality of the scrubber was improved.
                                                        The LWSC NMHC outlet concentration was improved by
                                                        93%(avg. 9.24 to 0.54ppm), effectively reducing the total
                                                        NMHC emissions at the chimney outlet by 0.50Ton/Year,
                                                        improving the factory chimney emission quality, meeting
                                                        the water quality refining requirements for air sewage
                                                        equipment, and reducing air pollution.
                                                        Keywords : NMHC, Washing Tower




              ��