VOL.51 廠務季刊 現址式燃燒洗滌塔 NOx 減量
表 2:DAS Styrax DRE test result table
Local scrubber condition N 2 O
Byproduct Ave.
Fuel/O 2 (LPM) Conc., ppm
Conc., ppm
ACC N 2
Inlet Outlet DRE
(%)
Fuel O 2 Ratio
Max. Max. NOx CO
#1 23.5 48.9 1/2 10% 106208 162.4 95.6% 166.4 N.D.
#2 23.5 48.8 1/2 60% 80802.7 58.3 97.3% 152.5 N.D.
#3 23.5 48 1/2 100% 140046.7 37.5 99.2% 130.9 N.D.
#4 23.5 44.1 1/1.9 100% 137482.4 50.1 98.9% 47 14.5
#5 21.5 40.5 1/1.9 100% 285266.8 107 98.1% 19.8 N.D.
#6 20.5 42.8 1/2 100% 291100 147.9 97.4% 24 N.D.
#7 21.5 44.8 1/2 100% 288061.4 128.8 98.3% 25.1 N.D.
#8 21.5 44.8 1/2 10% 286775.8 442.6 93.6% 31.4 N.D.
#9 21.5 44.8 1/2 60% 290818.4 185.8 97.2% 23.9 N.D.
#10 23.5 48.8 1/2 100% 287849.9 100.6 98.6% 23.3 N.D.
#11 23.5 48.8 1/2 60% 290388.3 106.3 98.4% 30 N.D.
#12 23.5 48.8 1/2 10% 287729.2 235.4 96.5% 50.1 N.D.
��